As the climate changes, overheating is becoming a growing challenge for the built environment. Homes are becoming increasingly difficult to live in during hotter summers, with impacts on occupant health and wellbeing.
Introduced as part of the Building Regulations in England, Part O was developed to address this challenge. Its purpose is simple: to ensure that new homes are designed to limit the risk of overheating and remain comfortable during hot weather.
Approved Document O was first published in December 2021 and came into effect on 15 June 2022. The current guidance remains the 2021 edition, although the government is reviewing its effectiveness and considering whether changes are needed.
Rather than relying on energy-intensive cooling systems, Part O encourages project teams to consider overheating risks early in the design process and the prioritisation of passive measures.
What is Part O?
Part O of the Building Regulations sets requirements for managing overheating risk in new residential buildings.
The regulation applies to residential dwellings (houses and flats), residential institutional buildings such as a care home, living accommodation, school or other similar establishment, where people sleep on the premises, and any form of student accommodation. It requires designers and developers to demonstrate that buildings have been designed to reduce unwanted solar gains during warmer periods while providing occupants with effective means of removing excess heat.
Why was Part O introduced?
Historically, homes in the UK have been designed primarily to retain heat during colder months. However, due to climate change, hotter summers and more frequent heatwave events are becoming increasingly common. At the same time, as buildings become more airtight and better insulated, there is a greater risk of overheating if design measures are not considered alongside energy efficiency.
Part O helps address this challenge by encouraging a balanced approach to building performance, recognising that homes must be able to stay cool as well as warm.
How can overheating risk be mitigated?
There is no single solution to mitigate overheating risk. Instead, effective design typically combines several strategies, including:
- Considering building orientation and layout from the outset.
- Managing solar gains through glazing design adjusted to different orientations.
- Limiting excessive glazing areas, particularly on west facing facades.
- Using external shading measures where required.
- Providing effective natural ventilation through safe openings.
- Ensuring occupants can remove excess heat during warmer periods.
The most successful approaches consider overheating as part of the overall building design, rather than attempting to solve the issue late in the project.
What does this mean for project teams?
Part O reinforces the importance of early-stage design decision-making.
Factors such as building orientation, façade design, glazing specifications and ventilation strategies can all influence overheating risk. Decisions made at concept stage may have significant implications for compliance later in the project lifecycle.
For developers and design teams, this means taking a more integrated approach to energy efficiency, occupant comfort and climate resilience.
Noise, security and occupant usability are also important considerations. Opening windows to provide ventilation may not always be practical, particularly at night or in areas exposed to high levels of external noise. Security concerns and window safety can also affect whether occupants are able to use natural ventilation effectively.
This means overheating strategies need to work in practice, balancing thermal comfort with noise, security and the needs of occupants.
What is changing?
The government’s Future Homes and Buildings Standards consultation included a call for evidence on Part O. The government published its response in March 2026 and committed to a full technical review of the standard, including its assessment methods, noise and security guidance, and the use of weather files.
As of October 2026, the Building Safety Regulator is undertaking this review and engaging with stakeholders. Any proposed regulatory or guidance changes will be informed by its findings, with further consultation to follow if changes are proposed.
Alongside this, CIBSE published the second edition of TM59, Overheating risk in dwellings: a design stage methodology, in July 2026. The updated methodology reflects current understanding of overheating risk, including updated weather files and assessment approaches.
This revised methodology is not however yet required under Part O (2021) and TM59:2017 remains the approved methodology.
Looking beyond compliance
While complying with Part O is a regulatory requirement, its importance extends beyond meeting Building Regulations.
Reducing overheating risk can improve occupant wellbeing, support climate resilience and minimise future reliance on mechanical cooling. It also helps ensure that homes designed today remain comfortable and functional in a changing climate.
As temperatures continue to rise, designing for overheating will become an increasingly important part of delivering sustainable, future-ready homes.
Looking ahead
Part O reflects a broader shift in the built environment. Building performance is no longer defined solely by energy efficiency or carbon reduction, but by how effectively buildings respond to the conditions they will face throughout their lifespan.
As the government reviews Part O and industry guidance continues to evolve, the focus is increasingly on ensuring that overheating assessments reflect future climate conditions and the practical needs of occupants.
By encouraging project teams to consider overheating from the outset, the regulation supports the delivery of homes that are better prepared for the realities of a warming climate.